Arc Fault Protection Systems
EV Solar & Battery Storage Ltd. provide solar fire protection and arc fault detection services in south-east England. Our service area is Buckinghamshire, Cambridgeshire, Hertfordshire, Northamptonshire, Oxfordshire, and Bedfordshire. We work for both commercial and residential clients: from small domestic solar systems to industrial-size solar farms.
Brands We Work With
Selected Products



Microinverters and DC voltage optimised systems were developed more than 10 years ago to prevent solar fires caused by DC arc faults. The two market leaders are SolarEdge and Enphase, both companies use a different approach to tackle this issue and differ by the design of their systems.
In a SolarEdge system each solar panel is connected to a voltage optimiser. In the event of a fault the system shuts down and reduces the voltage of each panel to 1v. This is known as SafeDC.
In an Enphase system each panel is connected to a micro-inverter. The only DC voltage present is between the solar panel and the microinverter where it is then converted to AC. If the microinverter detects a fault on the DC side it shuts down instantly. The DC voltage in an Enphase system doesn’t go above 80 volts.
Both these systems are very safe and worth the higher investment compared to string inverter based solar PV.
This isn’t as big an issue with AC systems. Electrical current can flow in two ways: alternating current (AC) and direct current (DC). The main difference between AC and DC is the way electrons flow. In an AC system electrons alternate between positive and negative, flowing back and forth in a circuit.
The associated voltage rises to, for example, 230 volts on the positive half of a cycle then rapidly drops, passing zero, before increasing again to 230 volts on the negative half of the cycle. This repeats very quickly which is known as the supply frequency. In the UK our electrical supply frequency is 50Hz; this means the AC voltage alternates between positive and negative 50 times per second.
Arcing is less of an issue in AC systems because they tend to self-extinguish as the voltage alternates passing through 0 volts. In a DC circuit current only flows in one direction and only on the positive half of the cycle, never passing zero. For an arc to be self-sustaining, the conditions for starting the arc must be present continuously. DC remains at a continuous voltage so once an arc has been established it will continue as long as the DC voltage is present and current is flowing.
Arc fault detection devices (AFDD’s) interrupt the flow of current which in turn extinguishes the arc.
N.B. Often a fault can start out as one type of fault (e.g. a series fault) and then develop into a different type of fault (e.g. parallel fault).